Protocol plugins:

Protocol plugin

/Feature

IEC 60870-5-104 clientIEC 60870-5-104 serverEDF HNZ clientIEC 60870-6 TASE.2 clientIEC 60870-6 TASE.2 serverIEC 60870-5-103 clientIEC 61850 MMS clientIEC 61850 MMS serverIEC 62541 OPCUA clientIEC 62541 OPCUA server
Connection management

COMPLETED

COMPLETED

COMPLETED

NOT YET IMPLEMENTED

IN PROGRESS

NOT YET IMPLEMENTED

COMPLETED

NOT YET IMPLEMENTED

NOT YET IMPLEMENTED

COMPLETED

Monitoring messages acquisition

COMPLETED

NOT APPLICABLE

COMPLETED

NOT YET IMPLEMENTED

NOT APPLICABLE

NOT YET IMPLEMENTED

COMPLETED

NOT APPLICABLE

NOT YET IMPLEMENTED

NOT APPLICABLE

Monitoring messages sending

NOT APPLICABLE

COMPLETED

NOT APPLICABLE

NOT APPLICABLE

IN PROGRESS

NOT APPLICABLE

NOT APPLICABLE

NOT YET IMPLEMENTED

NOT APPLICABLE

COMPLETED

Control messages acquisition

NOT APPLICABLE

COMPLETED

NOT APPLICABLE

NOT APPLICABLE

IN PROGRESS

NOT APPLICABLE

NOT APPLICABLE

NOT YET IMPLEMENTED

NOT APPLICABLE

COMPLETED

Control messages sending

COMPLETED

NOT APPLICABLE

COMPLETED

NOT YET IMPLEMENTED

NOT APPLICABLE

NOT YET IMPLEMENTED

COMPLETED

NOT APPLICABLE

NOT YET IMPLEMENTED

NOT APPLICABLE

Protocol stack configuration management

COMPLETED

COMPLETED

COMPLETED

NOT YET IMPLEMENTED

IN PROGRESS

NOT YET IMPLEMENTED

COMPLETED

NOT YET IMPLEMENTED

NOT YET IMPLEMENTED

COMPLETED

Exchanged messages configuration management

COMPLETED

COMPLETED

COMPLETED

NOT YET IMPLEMENTED

IN PROGRESS

NOT YET IMPLEMENTED

COMPLETED

NOT YET IMPLEMENTED

NOT YET IMPLEMENTED

COMPLETED

Clock synchronisation

COMPLETED

COMPLETED

COMPLETED

NOT YET IMPLEMENTED

IN PROGRESS

NOT YET IMPLEMENTED

NOT APPLICABLE

NOT YET IMPLEMENTED

NOT YET IMPLEMENTED

NOT APPLICABLE

General interrogation

COMPLETED

COMPLETED

COMPLETED

NOT YET IMPLEMENTED

IN PROGRESS

NOT YET IMPLEMENTED

COMPLETED

NOT YET IMPLEMENTED

NOT YET IMPLEMENTED

NOT APPLICABLE

Support for redundant connections

COMPLETED

COMPLETED

COMPLETED

NOT YET IMPLEMENTED

IN PROGRESS

NOT YET IMPLEMENTED

IN PROGRESS

NOT YET IMPLEMENTED

NOT YET IMPLEMENTED

COMPLETED

Exceptions, errors and logs management

COMPLETED

COMPLETED

COMPLETED

NOT YET IMPLEMENTED

IN PROGRESS

NOT YET IMPLEMENTED

COMPLETED

NOT YET IMPLEMENTED

NOT YET IMPLEMENTED

COMPLETED

Security

COMPLETED

COMPLETED

NOT YET IMPLEMENTED

NOT YET IMPLEMENTED

IN PROGRESS

NOT YET IMPLEMENTED

COMPLETED

NOT YET IMPLEMENTED

NOT YET IMPLEMENTED

COMPLETED

Filter plugins:

Filter pluginFeatureProgress
Fledgepower-filter-mvscale

performs math functions on pivot model measured values

COMPLETED

Fledgepower-filter-mvcyclingcheckchecks if a measured value has been received with a predefined period

COMPLETED

Fledgepower-filter-stampadds a timestamp to a status point received without timestamp

COMPLETED

Fledgepower-filter-transientsphandles transient status point

COMPLETED

Fledgepower-filter-pivottoopcuaconvert data from pivot model to opcua

COMPLETED

Fledgepower-filter-iec104topivotconvert data from pivot model to iec104

COMPLETED

Fledgepower-filter-pivottotase2convert data from pivot model to tase2

IN PROGRESS

Fledgepower-filter-pivottoiec103convert data from pivot model to iec103

NOT YET IMPLEMENTED

Fledgepower-filter-pivottohnzconvert data from pivot model to hnz

COMPLETED

Fledgepower-filter-iec104topivotconvert data from iec104 to pivot model

COMPLETED

Fledgepower-filter-opcuatopivotconvert data from opcua to pivot model

COMPLETED

Fledgepower-filter-tase2topivotconvert data from tase2 to pivot model

IN PROGRESS

Fledgepower-filter-iec103topivotconvert data from iec103 to pivot model

NOT YET IMPLEMENTED

Fledgepower-filter-hnztopivotconvert data from hnz to pivot model

COMPLETED

Legend:

NOT APPLICABLE feature is not applicable for this plugin

NOT YET IMPLEMENTED feature implementation not started yet

IN PROGRESS feature implementation in progress

COMPLETED feature implementation completed


  • No labels